L Lost Phase Identifier - NEW FEATURE ✓ +$70 Identifies which phase was bad during a Phase Loss event.
ADJ Phase Loss Time Delay Adjustment ✓ +$70 When a phase loss or phase unbalance is detected, this feature will delay the relay from tripping for the time period selected. Range is 0.5 to 30 seconds.
AUB Adjustable Unbalance ✓ +$70 This feature allows user to adjust the Phase Loss / Unbalance trip point. Available range is 5% to 15% phase unbalance.
R Reverse Phase Detection ✓ +$70 Often called negative phase sequence. This feature prevents motors from operating when phases are out of proper sequence by keeping the Phase Guard from resetting to normal until proper phase sequence is restored.
LV Low Voltage Detection ✓ +$70 Brownout protection. This feature will trip the relay when voltage on all 3 phases drop to 70% of nominal operating voltage and automatically reset when voltage returns to 90% of nominal. There is a 2 second delay built in to prevent nuisance tripping.
LVA Low Voltage Adjustment ✓ +$70 This feature allows user adjustment of the low voltage or brownout trip point. Available range is 70% to 87% of normal. Time delay can be set from 0.5 to 15 seconds. Requires Low Voltage Detection
O Overvoltage Detection ✓ +$70 This feature will trip the relay when voltage on all 3 phases exceeds 115% of nominal, and automatically reset when voltage returns to 105%. There is a 2 second delay built in to prevent nuisance tripping.
OVA Overvoltage Adjustment ✓ +$70 This feature allows user adjustment of the overvoltage trip point. Available range is 108% to 115% of normal. Time delay can be set from 0.5 to 15 seconds. Requires Overvoltage Detection
RTD Reset Time Delay Adjustment ✓ +$70 After the relay has tripped and normal voltage is restored, this feature will delay the relay from resetting to normal for the time period selected. Range is 0.5 seconds to 10 minutes and includes manual reset.
RS Normal Relay Selector ✓ +$70 This feature allows user to define whether the relay is normally Energized or De-energized.
PUT Power Up Time Delay ✓ +$70 Prevents the Phase Guard from functioning for a set time (0 seconds – 10 minutes) following a total outage. Delay possible from either Normal or Trip mode. Software selectable.
NOD Normal Operation Delay ✓ +$70 Prevents the Phase Guard from functioning for a set time (0 seconds – 10 minutes) after the relay resets to normal following a fault.
X Remote Display Module ✓ +$230 The Remote Display Module allows access of Phase-Guard function and features to move to a convenient panel location. More information ↗
XC CloudCom ✓ +$400 CloudCom allows you to stay connected with alerts from your Phase-Guard, delivered seamlessly through text messages and/or emails in real time. More information ↗